Blog - Chargers and charging

Charging individual cells using the regulated (laboratory) power supply

Charging individual cells using the regulated (laboratory) power supply

16.Feb 2018
| Blog - Chargers and charging

 

Charging individual cells using the regulated (laboratory) power supply

Many of the laboratory power supplies allow charging of the individual cells. Using such a regulated power supply is a suitable method for performing the initial charging or for the balancing of a single cell in a battery pack (by means of charging to a fixed voltage level).

There are usually 3 steps to follow:  1) set the target voltage (open voltage) – without the connection of the battery (3.65 at the picture), 2) start charging and set the current to be used (3.0 A at the picture), 3) when the charger reaches the target voltage – it usually starts to reduce the charging current until a low value. (3.66 V reached at 0.04A). It is a time to stop charging and disconnecting the charger.

46 visitors online.