Blog - Battery Monitoring

ELERIX EX-L12V100R Service Connector

ELERIX EX-L12V100R Service Connector

23.Mar 2022
| Blog - Battery Monitoring

The EX-L12V100R Service Connector is a magnetic 5-pin connector that allows direct access to the individual cells of the 12V battery.

The function of the connector is following

  • Measure the voltage of the individual cells.
  • Allow monitoring and connection of the BMS
  • Connect auxiliary devices to charge or balance individual cells
  • Integrate the battery into a large solution with direct access single cells. 

Warning: the maximal continuous load of the connector is 2 Amps. 

If you wish to use the magnetic connector to charge or balance individual cells, the current passed through the connector may not exceed 2 Amps. 

SHORT-CIRCUIT WARING

Warning:  the individual output pins are directly connected to the individual cells. There are no fuses, nor any other protection. 

You must avoid any short circuit by accidental connection of the pins or by improper wiring on the opposite part of the connector. 

Do not try to disassemble the service connector by removing the screws.